WE CALL IT THE FLEXBOX CONCEPT

The simple and flexible solution, to enable management of zone heating

Foreground image_GMB600.png
ESBE Manifold Box Series GMB600 >>

 

ESBE Manifold Box - Series GMB600

Becuase it's an extremely simple and flexible solution, to enable management of zone heating

background banner Flexbox.png

 

 

Combine circulation units according to the system's needs

 

ESBE CIRCULATION UNITS with insulation

The GxA300 series, DN20 uses the WILO PARA STG 15/8. 

ESBE Series GRA311.png

ESBE Series GRA311

Mixing function with 3-way motorized mixing valve
with progressive characteristic
ARA actuator

ESBE Series GDA311.png

ESBE Series GDA311

Direct supply
Three shut-off valves

ESBE Series GFA311.png

ESBE Series GFA311

Fixed temperature circulation with 
VTA thermostatic mixing valve, 20-55°C

 

ESBE CIRCULATION UNITS without insulation

The GxA390 series, DN20 uses the WILO Para 15/6/SCU.  

ESBE Series GRA394.png

ESBE Series GRA394

Knob for manually adjustment of the valve
ARA actuator and CRX controller as accessories 

ESBE Series GDA394.png

ESBE Series GDA394 

Direct supply
Three shut-off valves

ESBE Series GFA394.png

ESBE Series GFA394

Fixed temperature circulation with 
VTA thermostatic mixing valve, 20-55°C

 

 

 

 

ESBE MANIFOLD BOX - Series GMB600

ESBE Manifold Box Serie GMB600 is a distribution module for the management of two or three heating circuits, complemented with optional Circulation Units Serie Gxx300, DN20. The pre-assembled three circuit distribution manifold has two connection ports (left/right) for the supply line wich allows variable installation. The box is complete with an air-vent valve, wich allowes 360⁰ mounting.
The manifold is designed with a thermal separation between flow and return line and with integrated hydraulic separation, and the bypass function is easily controlled, using the 
adjustment screw. two connection ports (left/right) for the supply line.

 

flexbox.gif
Manual air-venting allows 90/180/270/360⁰ mounting of the unit

Oil and Gas_13_B.jpg

APPLICATON EXAMPLE 

The integrated hydralic separation in the GMB6xx is switched ON if the boiler doesn't include a circulation pump but the primary side is instead equiped like in this example,  a circulation unit GDA200.

 

 

 

 

 

 

POTENTIALS 

► Manifold with optional function for hydraulic separation easily set with a screw

► Two incoming ports for supply where one is plugged to avoid unnecessary piping 

► Connection of temperature sensor is possible. 

► Cover strip, to cover the transition between the box and the wall when its mounted inside the wall and two shut-off valves with colour coded thermometer can be added to the module.

► Space for installation of shut-off valves on the primary side, inside the box.

 

 

 

EASY TO INSTALL, EASY TO OWN

► Pre-prepared input and output holes makes the installation quick and neatly.

► Can be mounted on, or discreetly recessed into the wall

► High aesthetics with white epoxy metal casing, easy to open and close. 

► Pre-drilled holes for hanging and mounting.

► 360 degree mounting potential

 

The simple and flexible solution, to enable management of zone heating